title: 'Jaberg & Partner Unternehmensberatung: ☛ Draft tube flow investigation on an existing system'
url: 'https://www.jabergundpartner.com/en/news/news-and-activities/draft-tube-flow-investigation-at-a-powerplant/'
description: 'Numerical simulation for a turbine manufacturer: Investigation of the draft tube flow for turbine refurbishment of a hydropower plant in Hungary using CFD.'
image: 'https://www.jabergundpartner.com/fileadmin/user_upload/jabergundpartner/website_ueber_uns/jup_aktuelles_pix.jpg'
date: '2024-02-19'
modified: '2024-02-23'
lastUpdated: '2024-07-05'
---

# Jaberg & Partner Unternehmensberatung: ☛ Draft tube flow investigation on an existing system
[![](https://www.jabergundpartner.com/fileadmin/images/2024/JuP-logo-transparent.png)![](https://www.jabergundpartner.com/fileadmin/images/2024/JuP-logo-filled.png)](https://www.jabergundpartner.com/en/ "Prof. Dr. Jaberg & Partner GmbH")

![](https://www.jabergundpartner.com/fileadmin/_processed_/1/c/csm_jup_aktuelles_pix_1babb6c0e4.webp)

- [DE](https://www.jabergundpartner.com/de/news/aktivitaeten/untersuchung-der-saugrohrstroemung-an-einem-wasserkraftwerk/ "Deutsch")
- [](https://www.jabergundpartner.com/en/about-us/contact-us/)
- [](tel:+49624122575)
- [](https://www.jabergundpartner.com/en/about-us/contact-us/location/)

[![](https://www.jabergundpartner.com/fileadmin/images/2024/JuP-logo-transparent.png)](https://www.jabergundpartner.com/en/ "Prof. Dr. Jaberg & Partner GmbH")

- [ Tel:: +43 (0) 316 393188  ](tel:+43316393188)
- [Enquiry](https://www.jabergundpartner.com/en/about-us/contact-us/)
- [DE](https://www.jabergundpartner.com/de/news/aktivitaeten/untersuchung-der-saugrohrstroemung-an-einem-wasserkraftwerk/ "Deutsch")

Investigation of the draft tube flow
====================================

on an existing system
---------------------

We were commissioned by a leading turbine manufacturer to analyse the draft tube flow at an existing hydropower plant in Hungary using computational fluid dynamics (CFD).

As part of a refurbishment project, a decades-old Kaplan turbine has to be replaced by a new one. As both the spiral and the draft tube must remain basically unchanged, it was necessary to check whether the new, model-tested hydraulic design of the guide vane and runner could be combined with the existing components without any significant loss in efficiency. In detail, it had to be clarified whether the performance would be unfavourably influenced by the existing draft tube.

![](https://www.jabergundpartner.com/fileadmin/_processed_/e/5/csm_cfd_geschwindigkeitsverteilung_saugrohr_0d4e9fe250.webp "Velocity distribution in the draft tube")

Velocity distribution in the draft tube

In this case, it was mandatory to extend the flow area to be investigated to include the guide vane, runner, draft tube and underwater area in order to be able to analyse the interaction of the individual components, and in particular the runner-draft tube interaction.

[![](https://www.jabergundpartner.com/fileadmin/_processed_/3/0/csm_geometry_existing_d74077fadf.webp "Geometry: Existing")](https://www.jabergundpartner.com/fileadmin/_processed_/3/0/csm_geometry_existing_e0b7fca490.webp)

[![](https://www.jabergundpartner.com/fileadmin/_processed_/4/1/csm_geometry_manufacturer_fbc960b1bd.webp "Geometry: Manufacturer")](https://www.jabergundpartner.com/fileadmin/_processed_/4/1/csm_geometry_manufacturer_7ec847af2f.webp)

[![](https://www.jabergundpartner.com/fileadmin/_processed_/c/6/csm_geometry_optimised_7f202f1b7a.webp "Geometry: optimised")](https://www.jabergundpartner.com/fileadmin/_processed_/c/6/csm_geometry_optimised_ddfc912f77.webp)

Comparison of the analysed draft tube variants

In addition to the existing draft tube geometry, a design proposed by the manufacturer and a draft tube version optimised by Jaberg und Partner were analysed. In the end, a technically and economically optimised solution was found for the end customer in close collaboration with the client.

[Back to overview](https://www.jabergundpartner.com/en/news/news-and-activities/)

---

![](https://www.jabergundpartner.com/fileadmin/_processed_/9/5/csm_slider_newsletter_anmeldung_rabatt_pk_2020_2b3bff73ed.webp)

Subscribe and benefit
---------------------

Stay informed about our

- conferences
- continuing education programmes
- activities

[Subscribe Newsletter](https://www.jabergundpartner.com/en/landingpages/newsletter-registration-website-jaberg-partner/)

You are here:

- [Home](https://www.jabergundpartner.com/en/ "Home")
- [News](https://www.jabergundpartner.com/en/news/news-and-activities/ "News")
- [News and Activities](https://www.jabergundpartner.com/en/news/news-and-activities/ "News and Activities")

- [LinkedIn](https://www.linkedin.com/company/prof-dr-jaberg-und-partner-gmbh "LinkedIn")
- [Xing](https://www.xing.com/pages/prof-dr-jabergundpartnergmbh "Xing")

[ ![](https://www.jabergundpartner.com/fileadmin/images/footerlogo.png)](https://www.jabergundpartner.com/en/)

Prof.Dr.Jaberg & Partner GmbH Engineering & Consulting
Kerscheckstraße 41
8076 Vasoldsberg
Austria

Contact

- T [+43 (0) 316 393188](tel:+43316393188)
- [info@![](data:image/gif;base64,R0lGODlhAQABAIAAAP///wAAACH5BAEAAAAALAAAAAABAAEAAAICRAEAOw==)jabergundpartner.com](#)
- [www.jabergundpartner.com](https://www.jabergundpartner.com)

Service links

- [ Sitemap ](https://www.jabergundpartner.com/en/sitemap/ "Sitemap")
- [ Career ](https://www.jabergundpartner.com/en/about-us/career/ "Career")
- [ Academy ](https://www.jabergundpartner.com/en/academy/ "Academy")
- [ Imprint ](https://www.jabergundpartner.com/en/imprint/ "Imprint")
- [ Cookies & Privacy ](https://www.jabergundpartner.com/en/cookies-privacy/ "Cookies & Privacy")
- - [DE](https://www.jabergundpartner.com/de/news/aktivitaeten/untersuchung-der-saugrohrstroemung-an-einem-wasserkraftwerk/ "Deutsch")
    - [EN](https://www.jabergundpartner.com/en/news/news-and-activities/draft-tube-flow-investigation-at-a-powerplant/ "English")

[by bluechip.at](https://www.bluechip.at "by bluechip.at")