title: 'Jaberg & Partner Unternehmensberatung: ☛ CFD Flow Analysis of a Trifurcation in High-Head Hydropower'
url: 'https://www.jabergundpartner.com/en/news/news-and-activities/flow-analysis-and-optimisation-of-a-distribution-pipeline/'
description: 'CFD-based flow analysis and optimisation of a trifurcation used as a distribution manifold in a high-head hydropower plant with Pelton turbines'
image: 'https://www.jabergundpartner.com/fileadmin/user_upload/jabergundpartner/website_ueber_uns/jup_aktuelles_pix.jpg'
date: '2026-01-13'
modified: '2026-01-13'
lastUpdated: '2026-01-13'
---

# Jaberg & Partner Unternehmensberatung: ☛ CFD Flow Analysis of a Trifurcation in High-Head Hydropower
[![](https://www.jabergundpartner.com/fileadmin/images/2024/JuP-logo-transparent.png)![](https://www.jabergundpartner.com/fileadmin/images/2024/JuP-logo-filled.png)](https://www.jabergundpartner.com/en/ "Prof. Dr. Jaberg & Partner GmbH")

![](https://www.jabergundpartner.com/fileadmin/_processed_/1/c/csm_jup_aktuelles_pix_1babb6c0e4.webp)

- [DE](https://www.jabergundpartner.com/de/news/aktivitaeten/stroemungsanalyse-und-optimierung-einer-verteilrohrleitung/ "Deutsch")
- [](https://www.jabergundpartner.com/en/about-us/contact-us/)
- [](tel:+49624122575)
- [](https://www.jabergundpartner.com/en/about-us/contact-us/location/)

[![](https://www.jabergundpartner.com/fileadmin/images/2024/JuP-logo-transparent.png)](https://www.jabergundpartner.com/en/ "Prof. Dr. Jaberg & Partner GmbH")

- [ Tel:: +43 (0) 316 393188  ](tel:+43316393188)
- [Enquiry](https://www.jabergundpartner.com/en/about-us/contact-us/)
- [DE](https://www.jabergundpartner.com/de/news/aktivitaeten/stroemungsanalyse-und-optimierung-einer-verteilrohrleitung/ "Deutsch")

Flow analysis and optimisation
==============================

of a trifurcation as a distribution pipeline for a high-pressure hydropower plant
---------------------------------------------------------------------------------

For a new high-pressure hydropower plant with three Pelton turbines (2 x 8.4 MW, 1 x 5.4 MW), the distribution pipeline is to be designed as a trifurcation.

### Flow analysis of a trifurcation: challenges in the design

However, the task of designing such pipe junctions, which at first glance appears simple, has often proved problematic in the past. The inevitable deceleration of flow at the junction of a triple branch is highly susceptible to separation, which can lead not only to flow losses but also to pulsations in the individual pipe strands.

### CFD-based optimisation of trifurcation geometry to minimise hydraulic losses

On behalf of a turbine manufacturer, we recently carried out a flow analysis and optimisation of the corresponding distribution pipeline. Using the initial design as an example, the following figure shows the velocity distribution at different cross-sectional planes for full-load operation of all three turbines. The unfavourable flow situation identified at the trifurcation junction (see dark blue areas) is clearly evident.

![](https://www.jabergundpartner.com/fileadmin/_processed_/0/3/csm_verteilrohrleitung_db2a35b58e.webp)Velocity distribution at different section planes in the distribution pipe referring to the initial design proposal

Following several design adjustments, the flow situation was ultimately significantly improved, and a satisfactory result was achieved.

[Back to overview](https://www.jabergundpartner.com/en/news/news-and-activities/)

---

![](https://www.jabergundpartner.com/fileadmin/_processed_/9/5/csm_slider_newsletter_anmeldung_rabatt_pk_2020_2b3bff73ed.webp)

Subscribe and benefit
---------------------

Stay informed about our

- conferences
- continuing education programmes
- activities

[Subscribe Newsletter](https://www.jabergundpartner.com/en/landingpages/newsletter-registration-website-jaberg-partner/)

You are here:

- [Home](https://www.jabergundpartner.com/en/ "Home")
- [News](https://www.jabergundpartner.com/en/news/news-and-activities/ "News")
- [News and Activities](https://www.jabergundpartner.com/en/news/news-and-activities/ "News and Activities")

- [LinkedIn](https://www.linkedin.com/company/prof-dr-jaberg-und-partner-gmbh "LinkedIn")
- [Xing](https://www.xing.com/pages/prof-dr-jabergundpartnergmbh "Xing")

[ ![](https://www.jabergundpartner.com/fileadmin/images/footerlogo.png)](https://www.jabergundpartner.com/en/)

Prof.Dr.Jaberg & Partner GmbH Engineering & Consulting
Kerscheckstraße 41
8076 Vasoldsberg
Austria

Contact

- T [+43 (0) 316 393188](tel:+43316393188)
- [info@![](data:image/gif;base64,R0lGODlhAQABAIAAAP///wAAACH5BAEAAAAALAAAAAABAAEAAAICRAEAOw==)jabergundpartner.com](#)
- [www.jabergundpartner.com](https://www.jabergundpartner.com)

Service links

- [ Sitemap ](https://www.jabergundpartner.com/en/sitemap/ "Sitemap")
- [ Career ](https://www.jabergundpartner.com/en/about-us/career/ "Career")
- [ Academy ](https://www.jabergundpartner.com/en/academy/ "Academy")
- [ Imprint ](https://www.jabergundpartner.com/en/imprint/ "Imprint")
- [ Cookies & Privacy ](https://www.jabergundpartner.com/en/cookies-privacy/ "Cookies & Privacy")
- - [DE](https://www.jabergundpartner.com/de/news/aktivitaeten/stroemungsanalyse-und-optimierung-einer-verteilrohrleitung/ "Deutsch")
    - [EN](https://www.jabergundpartner.com/en/news/news-and-activities/flow-analysis-and-optimisation-of-a-distribution-pipeline/ "English")

[by bluechip.at](https://www.bluechip.at "by bluechip.at")