description: 'Comprehensive CFD simulation shows causes for the performance deficit of a historic twin Francis turbine.'
image: 'https://www.jabergundpartner.com/fileadmin/user_upload/jabergundpartner/website_ueber_uns/jup_aktuelles_pix.jpg'
date: '2024-02-19'
modified: '2024-02-19'
lastUpdated: '2024-07-05'
---

# Jaberg & Partner Unternehmensberatung: ☛ Flow analysis on an overhauled twin Francis turbine
[![](https://www.jabergundpartner.com/fileadmin/images/2024/JuP-logo-transparent.png)![](https://www.jabergundpartner.com/fileadmin/images/2024/JuP-logo-filled.png)](https://www.jabergundpartner.com/en/ "Prof. Dr. Jaberg & Partner GmbH")

![](https://www.jabergundpartner.com/fileadmin/_processed_/1/c/csm_jup_aktuelles_pix_1babb6c0e4.webp)

- [DE](https://www.jabergundpartner.com/de/news/aktivitaeten/stroemungsanalyse-an-einer-zwillings-francis-turbine/ "Deutsch")
- [](https://www.jabergundpartner.com/en/about-us/contact-us/)
- [](tel:+49624122575)
- [](https://www.jabergundpartner.com/en/about-us/contact-us/location/)

[![](https://www.jabergundpartner.com/fileadmin/images/2024/JuP-logo-transparent.png)](https://www.jabergundpartner.com/en/ "Prof. Dr. Jaberg & Partner GmbH")

- [ Tel:: +43 (0) 316 393188  ](tel:+43316393188)
- [Enquiry](https://www.jabergundpartner.com/en/about-us/contact-us/)
- [DE](https://www.jabergundpartner.com/de/news/aktivitaeten/stroemungsanalyse-an-einer-zwillings-francis-turbine/ "Deutsch")

Flow analysis on an overhauled
==============================

twin Francis turbine
====================

to prove and justify the identified performance deficit
-------------------------------------------------------

In course of the refurbishment of a historic Italian Camelback Francis-turbine built in 1924, a completely new Camelback-unit was supplied in 2022. The only parts of the power plant that remained unchanged were the intake and the draft tube downstream of the twin-manifold which diverts the flow from the two horizontal turbine runners in a vertical direction. In course of the commissioning it quickly turned out that there is a quite massive lack of power generated by the turbine.

![](https://www.jabergundpartner.com/fileadmin/_processed_/f/5/csm_camelback_turbine_6909634367.webp "Twin Francis Turbine")3D streamlines at full load operation of the analysed twin Francis turbine

With the help of a comprehensive CFD-simulation we analysed the flow in the Twin-type Camelback turbine to find out the reasons for the performance deficit. The findings of the CFD-study fully confirmed the operation experience of the turbine.

While there might also be some room for improvement of the runner design, the main problem of the turbine is the unfavourable design of the twin-manifold and the main draft tube. Finally, we developed suggestions on how to significantly improve turbine performance.

[Back to overview](https://www.jabergundpartner.com/en/news/news-and-activities/)

---

![](https://www.jabergundpartner.com/fileadmin/_processed_/9/5/csm_slider_newsletter_anmeldung_rabatt_pk_2020_2b3bff73ed.webp)

Subscribe and benefit
---------------------

Stay informed about our

- conferences
- continuing education programmes
- activities

[Subscribe Newsletter](https://www.jabergundpartner.com/en/landingpages/newsletter-registration-website-jaberg-partner/)

You are here:

- [Home](https://www.jabergundpartner.com/en/ "Home")
- [News](https://www.jabergundpartner.com/en/news/news-and-activities/ "News")
- [News and Activities](https://www.jabergundpartner.com/en/news/news-and-activities/ "News and Activities")

- [LinkedIn](https://www.linkedin.com/company/prof-dr-jaberg-und-partner-gmbh "LinkedIn")
- [Xing](https://www.xing.com/pages/prof-dr-jabergundpartnergmbh "Xing")

[ ![](https://www.jabergundpartner.com/fileadmin/images/footerlogo.png)](https://www.jabergundpartner.com/en/)

Prof.Dr.Jaberg & Partner GmbH Engineering & Consulting
Kerscheckstraße 41
8076 Vasoldsberg
Austria

Contact

- T [+43 (0) 316 393188](tel:+43316393188)
- [info@![](data:image/gif;base64,R0lGODlhAQABAIAAAP///wAAACH5BAEAAAAALAAAAAABAAEAAAICRAEAOw==)jabergundpartner.com](#)
- [www.jabergundpartner.com](https://www.jabergundpartner.com)

Service links

- [ Sitemap ](https://www.jabergundpartner.com/en/sitemap/ "Sitemap")
- [ Career ](https://www.jabergundpartner.com/en/about-us/career/ "Career")
- [ Academy ](https://www.jabergundpartner.com/en/academy/ "Academy")
- [ Imprint ](https://www.jabergundpartner.com/en/imprint/ "Imprint")
- [ Cookies & Privacy ](https://www.jabergundpartner.com/en/cookies-privacy/ "Cookies & Privacy")
- - [DE](https://www.jabergundpartner.com/de/news/aktivitaeten/stroemungsanalyse-an-einer-zwillings-francis-turbine/ "Deutsch")
    - [EN](https://www.jabergundpartner.com/en/news/news-and-activities/flow-analysis-on-twin-francis-turbine/ "English")

[by bluechip.at](https://www.bluechip.at "by bluechip.at")